{"product_id":"victron-lynx-shunt-vecan-m10-lyn040102110","title":"Victron Lynx Shunt VE.Can M10 - 1000A Intelligent Battery Monitor - LYN040102110","description":"\u003ch2\u003e1000A Victron Lynx M10 busbar with a built-in battery monitor and flexible main fuse holder\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eNeeds a Victron GX device (such as a Cerbo GX) to show the battery readings. Main system fuse sold separately.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eThe Victron Lynx Shunt VE.Can M10 sits between your battery bank and the rest of a 12V, 24V or 48V DC system. It carries up to 1000A, holds a CNN, ANL or Mega main fuse and measures everything flowing in and out of the battery, so your GX device can show state of charge, time to go and alarms, on site or remotely in the VRM portal.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"buzz-benefits\"\u003e\n\u003cdiv class=\"buzz-benefit\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #fc9300;\"\u003eBattery monitor built in\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eA shunt in the negative busbar measures every amp in and out of the battery, so there is no separate battery monitor to buy or wire.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"buzz-benefit\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #fc9300;\"\u003eFuse it your way\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eTakes a CNN, ANL or Mega main fuse, or fit the included fuse dummy busbar and put a larger main fuse elsewhere in the system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"buzz-benefit\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #fc9300;\"\u003eTemperature sensor included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe battery temperature sensor comes in the box, so battery temperature shows on your GX device and can drive the alarm relay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLynx Shunt VE.Can M10 Main Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000A continuous rating\u003c\/strong\u003e: carries up to 1000A DC, which is about 12kW at 12V, 24kW at 24V and 48kW at 48V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull battery monitoring\u003c\/strong\u003e: battery voltage, current, power, state of charge, amp hours used and time to go, shown on your GX device and in the VRM portal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree main fuse options\u003c\/strong\u003e: holds a CNN or ANL fuse on M8 bolts, or a Mega fuse on M6 bolts. The \u003ca style=\"color: #fc9300; text-decoration: underline;\" rel=\"noopener\" href=\"https:\/\/buzz.energy\/products\/victron-fuse-cnn-325a-80v-for-lynx-shunt-1-pc-cip140325000\" target=\"_blank\"\u003eVictron CNN 325A\/80V fuse\u003c\/a\u003e fits and is sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse dummy busbar included\u003c\/strong\u003e: fit the supplied piece of busbar in place of the fuse to mount the main fuse outside the shunt, useful in larger systems that need a higher rated fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse monitoring\u003c\/strong\u003e: when the fuse is in the shunt, a blown fuse turns the power LED red and sends an alarm to the GX device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Can communication\u003c\/strong\u003e: connects to a \u003ca style=\"color: #fc9300; text-decoration: underline;\" rel=\"noopener\" href=\"https:\/\/buzz.energy\/products\/victron-cerbo-gx-mk2-bpp900451100\" target=\"_blank\"\u003eCerbo GX\u003c\/a\u003e or other Victron GX device for monitoring and setup. Two RJ45 VE.Can terminators are in the box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable alarm relay\u003c\/strong\u003e: potential free contact rated 3A at 30Vdc or 250Vac, set from the GX device to switch on state of charge, battery voltage, battery temperature or a blown fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery temperature sensor\u003c\/strong\u003e: included, with ferrules and terminal block. Temperature is logged on the GX device and VRM and can drive the relay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHistory log\u003c\/strong\u003e: records lowest and highest battery voltage, total amp hours drawn, synchronisation count and alarm counts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNMEA 2000 ready\u003c\/strong\u003e: joins a boat's NMEA 2000 network through its VE.Can port with a VE.Can to NMEA 2000 micro-C cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Lynx design\u003c\/strong\u003e: bolts straight onto other M10 Lynx modules, such as the \u003ca style=\"color: #fc9300; text-decoration: underline;\" rel=\"noopener\" href=\"https:\/\/buzz.energy\/products\/victron-lynx-power-in-m10-lyn020102010\" target=\"_blank\"\u003eLynx Power In (M10)\u003c\/a\u003e and \u003ca style=\"color: #fc9300; text-decoration: underline;\" rel=\"noopener\" href=\"https:\/\/buzz.energy\/products\/victron-lynx-distributor-m10-lyn060102010\" target=\"_blank\"\u003eLynx Distributor (M10)\u003c\/a\u003e, to form one continuous busbar. Batteries connect on the left, loads and chargers on the right.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/OWJvDYDkl5E\" title=\"Explanation of Victron Energy Lynx Shunt\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3\u003eQuick Specs:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel: LYN040102110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCurrent rating: 1000A DC continuous\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSupported system voltages: 12V, 24V or 48V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSupply voltage range: 9 to 70Vdc\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower consumption: 60mA at 12V, 33mA at 24V, 20mA at 48V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBusbar connections: M10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFuse or fuse dummy: M8 bolts (Mega fuse on M6 bolts)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBusbar: tinned copper, 8 x 30 mm\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAlarm relay: 3A, 30Vdc \/ 250Vac\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eReverse polarity protection: No\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions (h x w x d): 190 x 180 x 80 mm\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight: 1.4kg\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eProtection class: IP22\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOperating temperature: -40°C to +60°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's Included:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Victron Lynx Shunt VE.Can M10 (LYN040102110)\u003c\/li\u003e\n\u003cli\u003e2x RJ45 VE.Can terminators\u003c\/li\u003e\n\u003cli\u003e1x battery temperature sensor (ASS000001000) with ferrules and terminal block\u003c\/li\u003e\n\u003cli\u003e1x fuse dummy (piece of busbar)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"buzz-callout buzz-callout--warn\"\u003e\n\u003cstrong\u003e\u003cspan class=\"buzz-callout__title\"\u003eBefore you order\u003c\/span\u003e\u003c\/strong\u003e\n\u003cp\u003eThe Lynx Shunt VE.Can is read and set up on a Victron GX device, such as the \u003ca style=\"color: #fc9300; text-decoration: underline;\" rel=\"noopener\" href=\"https:\/\/buzz.energy\/products\/victron-cerbo-gx-mk2-bpp900451100\" target=\"_blank\"\u003eCerbo GX\u003c\/a\u003e, so your system needs one. The main system fuse is not included. M10 Lynx modules cannot bolt directly to older M8 Lynx modules, so match the busbar size when adding to an existing system. There is no reverse polarity protection, so check polarity before connecting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/3141\/0749\/files\/Victron_Lynx_Shunt_VE.Can_M8_M10_DATASHEET.pdf?v=1791171710\" title=\"Victron Lynx Shunt VE.Can M8 and M10 DATASHEET\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eClick Here To View Victron Lynx Shunt VE.Can DATASHEET\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eManual\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/3141\/0749\/files\/Victron_Lynx_Shunt_VE.Can_M10_MANUAL.pdf?v=1791171704\" title=\"Victron Lynx Shunt VE.Can (M10) MANUAL\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eClick Here To View Victron Lynx Shunt VE.Can (M10) MANUAL\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eWarranty\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/3141\/0749\/files\/Victron_Energy_Limited_Warranty_Policy_DOCUMENT.pdf?v=1725846185\" title=\"Victron Energy Limited Warranty Policy DOCUMENT\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eClick Here To View Victron Energy Limited Warranty Policy DOCUMENT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52954619150653,"sku":"LYN040102110","price":497.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/3141\/0749\/files\/44e34581-82c1-440e-a8af-7e0c17b4f3fc.jpg?v=1788262499","url":"https:\/\/buzz.energy\/products\/victron-lynx-shunt-vecan-m10-lyn040102110","provider":"Buzz.energy","version":"1.0","type":"link"}